Handscan - Mini (MFL) magnetic flux leakage
corrosion screen system
Click for video
The Handscan MFL corrosion detection mini scanner is designed to compliment the, MFL 2000 and FloormapVS2i floorscanners. Even in such a small configuration the latest generation of permanent magnets enable localized magnetic saturation of the floor area under test.
Signals from corrosion, above the operator controllable threshold, are displayed as both a visual and audible alarm. It’s low profile and extendable handle allow scanning in otherwise inaccessible areas of storage tanks such as the shell to annular area and under pipe work or heater coils.
Key Features
- Low Profile with Extendable Handle
- Suitable for Shell to Annular Areas and Under Pipe Work
- Latest Generation Permanent Magnet Technology
- Separate Battery Operated Lightweight Electronic Module
- Easy to Use, Cost Effective Inspection Tool
Handscan - Technical and Performance Specification
|
Principle of operation |
Magnetic Flux Leakage |
|
Detection |
18 off Hall Effect sensors |
|
Scan width |
150 mm |
|
Method of propulsion |
Hand Push / Pull |
|
Speed |
0.5m/ sec |
|
Handle |
Extendable handle supplied
|
|
Profile
|
Clearance under pipework
required 120 mm |
|
Thickness range |
Maximum 15 mm
|
|
Test through coatings |
Yes if non magnetic |
|
Maximum coating thickness |
6mm |
|
Sensitivity |
adjustable |
|
Max sensitivity |
10% underfloor on un-coated 6 mm plate
20% underfloor on coated 6 mm plate |
|
Connecting Cable |
5 metre standard length
|
|
Power requirements |
12v battery operation
|
|
Test Time |
10 hour continuous working
|
|
Transit case |
Meets IATA requirements for transporting
magnetizable material |
|
Operating weight |
18 Kg - combined weight of
scanning head and electronics module |