| Principle of operation |
Magnetic Flux Leakage |
| Detection |
36 off Hall Effect sensors |
| Scan width |
300 mm |
| Method of propulsion |
DC Motor |
| Speed |
0.5 m/sec |
| Thickness range |
Maximum 20 mm |
| Test through coatings |
Yes if non magnetic |
| Maximum coating thickness |
6 mm |
| Sensitivity |
adjustable |
| Max sensitivity |
10% underfloor on un-coated 6 mm plate
20% underfloor on coated 6 mm plate |
| Auto stop |
Yes |
| Power requirements |
12v battery operation
1 x 28 Ah battery supplied and 1 intelligent charger allowing 10 hours continuous working |
| Transit case |
Meets IATA requirements for transporting magnetizable
material |
| Operating weight |
47 Kg |