| Principle of operation |
Magnetic Flux Leakage |
| Detection |
18 off Hall Effect sensors |
| Pipe diameters |
48 mm to 2.4 metre - Outside Diameter |
| Method of propulsion |
Hand Push / Pull |
| Speed |
0.5 m/sec |
| Profile |
Clearance under / between pipework min 120 mm |
| Thickness range |
Maximum 19 mm |
| Test through coatings |
Yes if non magnetic |
| Maximum coating thickness |
6 mm |
| Sensitivity |
Adjustable |
| Max sensitivity |
30% pitting in 6 mm wall pipe
40% pitting in 12 mm wall pipe
50% pitting in 19 mm wall pipe |
| Connecting Cable |
5 metre standard length |
| Power requirements |
12v battery operation |
| Test Time |
10 hour continuous working |
| Transit case |
Meets IATA requirements for transporting magnetizable material |
| Operating weight |
18 Kg - combined weight of scanning head and electronics module |